Electrode Placement Guide

Recovery Muscle Clinical Support

Electrode Placement & Programme Guide

Practical electrode placement and programme guidance for common rehabilitation applications. Select a treatment area to explore electrode positioning, electrode selection and Recovery Muscle programme guidance.

✓ Clinic & Home Use ✓ Dual-Channel NMES ✓ Electrode Placement Guidance ✓ Rehabilitation Programme Support
Recovery Muscle interactive electrode placement guide showing common treatment areas
Interactive Placement & Programme Guidance

Select Your Treatment Area

Choose an area below to view the placement illustration, recommended electrode configuration and rehabilitation programme guidance.

Electrode Placement

Recovery Muscle electrode placement illustration
Electrode positions provide practical placement guidance. Individual anatomy varies and small positional adjustments may be required to achieve the intended muscular response.
Primary Objective
Recommended Electrodes
Configuration

Placement Guidance

Recommended Programme

What You Should Look For

Programme Guide

Programme selection should reflect the rehabilitation objective and stage of recovery. The treatment guidance above provides practical recommendations for common rehabilitation applications.
P1
Strengthening Rehabilitation
Progressive muscle strengthening, functional strength and muscular endurance.
P2
Atrophy & Muscle Rehabilitation
Rehabilitation of weakened or atrophied muscle and rebuilding muscle condition and mass.
P3
Neurological Rehabilitation
Early muscle activation, neurological rehabilitation and neuromuscular re-education.
P4
Facial Palsy Rehabilitation
Low-frequency facial muscle activation and neuromuscular re-education.
Important Safety & Application Information

This guide provides practical Recovery Muscle application guidance and does not replace the Instructions for Use supplied with your device or individual advice from your healthcare professional.

  • Ensure electrodes make full and even contact with clean, intact skin.
  • Individual anatomy varies. Small adjustments in electrode position may be required to obtain the intended muscular response.
  • Do not place electrodes over broken, irritated or infected skin.
  • Always follow the contraindications, warnings and precautions contained within the device Instructions for Use.
  • Where a physiotherapist or other healthcare professional has provided individual placement or programme instructions, follow their guidance.